T&E Pumps - Standard Series

T&E Pumps manufactures the highest quality of Positive Displacement Fluid Pumps.  Designed with oil hauling in mind, our pumps can also be used for moving numerous types of other fluids. Use the "Pumps & Care" drop down menu to find out about each of our product lines. For additional information please call us toll free, we look forward to hearing from you. We install, sell and service direct!

2100 Series Std. Pump (513W/513WNT)
2100 (180°) Series Pump Features:
• 2100 series straight through T&E cast housing with 2” inlet & outlet.
• Available with optional nitrided housing, Teflon seals, outboard gear case assembly, or direct drive hydraulic motor mount.
• 2” threaded flanges.
• 4” helical-cut, nitrided steel gears.
• Requires a minimum 2” hose & fitting.
2100-513W-HI RES.jpg
Part Numbers:
• 513W                 
• 513WNT              
• 513W-OBF         
• 513WD   
2” T&E 180° cast housing/steel gears/bushing caps/black gaskets.
2” T&E 180° nitrided housing/steel gears/Teflon seals/blue gaskets.
2” T&E 180° with outboard gear case assembly.
2” T&E 180° with direct drive hydraulic motor mount.
Horsepower Requirements:
• Hydraulic Motor 20hp.
            o 104 Series Recommended.
• Electric Motor 5-10hp with 440 VFD.
Recommended Operating Procedures:
• Maximum Temp: 
• Maximum RPM: 
• Maximum Pressure:
212°F (regular seals).
750 RPM at the pump.
125 PSI. 
o Note: Pump pressure is maximum safe operating pressure, not the maximum pressure the pump will produce.
Tested Flow Rates:
2100-513-FLOW-LPM.jpg
Installation Dimensions:
513W- REVA INSTALLATION DIMS.png
4000 Series Std. Pump (110W/110WNT)
4000 (180°) Series Pump Features:
• 4000 series straight through T&E cast housing with 4” inlet & outlet.
• Available with optional nitrided housing, Teflon seals, outboard gear case assembly, or direct drive hydraulic motor mount.
• 4” steel weld flanges.
• 6” helical-cut, nitrided steel gears.
• Requires a minimum 3” hose & fitting.
• Eco Pump Option available with Rubber Gears (See ECO Pump)
4000-110W-HI RES.jpg
Part Numbers:
• 110W                4” T&E 180° cast housing/steel gears/bushing caps/black gaskets.
• 110WNT          4” T&E 180° nitrided housing/steel gears/bushing caps/Teflon seals/ blue gaskets.
• 110WD             4” T&E 180° with direct drive hydraulic motor mount.
• 110W-OBF      4” T&E 180° with outboard gear case assembly.
Horsepower Requirements:
• Hydraulic Motor 30-40hp.
            o 109 Series Recommended.
• Electric Motor 15-20hp with 440 VFD.
Recommended Operating Procedures:
• Maximum Temp: 
• Maximum RPM: 
• Maximum Pressure:
212°F (regular seals).
750 RPM at the pump.
125 PSI. 
o Note: Pump pressure is maximum safe operating pressure, not the maximum pressure the pump will produce.
Tested Flow Rates:
4000-110-FLOW-LPM.jpg
Installation Dimensions:
110W- REVA INSTALLATION DIMS IMAGE MARCH 2022.png
4000R Series Std. Pump (114RW/114RWNT)
4000R (90°) Series Pump Features:
• Small body right angle T&E cast housing with 4” inlet & outlet.
• Available with optional nitrided housing, Teflon seals, outboard gear case assembly, or direct drive hydraulic motor mount.
• 4” steel weld flanges.
• 7.5” helical-cut, nitrided steel gears.
• Requires a minimum 3” hose & fitting.
4000R-114RW-HI RES.jpg
Part Numbers:
• 114RW             4” T&E 90° cast housing/steel gears/bushing caps/black gaskets.
• 114RWNT       4” T&E 90° nitrided housing/steel gears/bushing caps/Teflon seals/ blue gaskets.
• 114RWD          4” T&E 90° with direct drive hydraulic motor mount.
• 114RW-OBF   4” T&E 90° with outboard gear case assembly.
Horsepower Requirements:
• Hydraulic Motor 30-40hp.
            o 109 Series Recommended.
• Electric Motor 15-20hp with 440 VFD.
Recommended Operating Procedures:
• Maximum Temp: 
• Maximum RPM: 
• Maximum Pressure:
212°F (regular seals).
750 RPM at the pump.
125 PSI. 
o Note: Pump pressure is maximum safe operating pressure, not the maximum pressure the pump will produce.
Tested Flow Rates:
4000R-114RW-FLOW-LPM.jpg
Installation Dimensions:
114RW-REVC Installation DIMS.png
4100 Series Std. Pump (216W/216WNT)
4100 (180°) Series Pump Features:
• 4100 Series straight through T&E cast housing with 4.5” inlet & outlet.
• Available with optional nitrided housing, Teflon seals, outboard gear case assembly, or direct drive hydraulic motor mount.
• 5” steel weld flanges.
• 7.25” helical-cut, nitrided steel gears.
• Requires a minimum 4” hose & fitting.
4100-216W-HI RES.jpg
Part Numbers:
• 216RW            5” T&E 180° cast housing/steel gears/bushing caps/black gaskets.
• 216WNT         5” T&E 180° nitrided housing/steel gears/bushing caps/Teflon seals/ blue gaskets.
• 216WD            5” T&E 180° with direct drive hydraulic motor mount.
• 216W-OBF     5” T&E 90° with outboard gear case assembly.
Horsepower Requirements:
• Hydraulic Motor 50-60hp.
            o 112 Series Recommended.
• Electric Motor 20hp with 440 VFD.
Recommended Operating Procedures:
• Maximum Temp: 
• Maximum RPM: 
• Maximum Pressure:
212°F (regular seals).
750 RPM at the pump.
125 PSI. 
o Note: Pump pressure is maximum safe operating pressure, not the maximum pressure the pump will produce.
Tested Flow Rates:
4100-216-FLOW-LPM.jpg
Installation Dimensions:
216W Installation Dims r1.png
4100R Series Std. Pump (214RW/214RWNT)
4100R (90°) Series Pump Features:
• 4100 Series 90° T&E cast housing with 5” inlet & outlet.
• 5” steel weld flanges.
• 7.25” helical-cut, nitrided steel gears.
• Requires a minimum 4” hose & fitting.
4100R-214RW-HI RES.jpg
Part Numbers:
• 214RW            5” T&E 90° cast housing/steel gears/bushing caps/black gaskets.
Horsepower Requirements:
• Hydraulic Motor 50-60hp.
            o 112 Series Recommended.
• Electric Motor 20hp with 440 VFD.
Recommended Operating Procedures:
• Maximum Temp: 
• Maximum RPM: 
• Maximum Pressure:
212°F (regular seals).
850 RPM at the pump.
125 PSI. 
o Note: Pump pressure is maximum safe operating pressure, not the maximum pressure the pump will produce.
Tested Flow Rates:
4100R-214RW-FLOW-LPM.jpg
Installation Dimensions:
214RW-INSTALLATION DIMS-IMAGE.png